Review



monochromatic cmos camera  (Basler)


Bioz Verified Symbol Basler is a verified supplier
Bioz Manufacturer Symbol Basler manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Basler monochromatic cmos camera
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Monochromatic Cmos Camera, supplied by Basler, used in various techniques. Bioz Stars score: 93/100, based on 50 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/acA2040-180km/pmc12795430-32-8-12
    Average 93 stars, based on 50 article reviews
    monochromatic cmos camera - by Bioz Stars, 2026-11
    93/100 stars

    Images

    1) Product Images from "qtOCT: quantitative transmission optical coherence tomography"

    Article Title: qtOCT: quantitative transmission optical coherence tomography

    Journal: Biomedical Optics Express

    doi: 10.1364/BOE.580168

    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − CMOS camera.
    Figure Legend Snippet: Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − CMOS camera.

    Techniques Used: Microscopy

    Related Articles

    other:

    Article Title: Responding to the signal and the noise: behavior of planktonic gastropod larvae in turbulence.
    Article Snippet: A center-plane of the tank was illuminated with a near-IR pulsed laser (Oxford Firefly FF1000, 300 W), and imaged with a monochromatic CMOS camera (Basler acA2040-90umNIR) equipped with a Nikon micro 105 mm f/2.8 lens.

    Article Title: Multi-functional broadband diffractive neural network with a single spatial light modulator
    Article Snippet: The second task is the classification of images of hand-written digits in the MNIST database, in which the detector is a monochromatic CMOS camera (Basler ace acA5472-17um).

    Article Title: High-Performance Plasmonic Hafnium Nitride Nanocavity and Nanodisk Arrays for Enhanced Refractometric Sensing
    Article Snippet: As the light source, we utilized a fiber-coupled tungsten halogen lamp (Ocean Optics, HL-2000-HP) and collimated it into the illumination arm of the microscope.

    Imaging:

    Article Title: Backtracking Reconstruction Network for Three-Dimensional Compressed Hyperspectral Imaging
    Article Snippet: .. The testbed consisted of a fiber ring illuminator (Thorlabs FRI61F50 and OSL2), an imaging lens with a focal length of 50 mm, a visible LCTF with a range of 500 nm–710 nm, two relay lenses with a focal length of 75 mm, a DMD (Texas Instruments DLP9500), and a monochromatic CMOS camera (Basler acA2040-90 um). .. The testbed consisted of a fiber ring illuminator (Thorlabs FRI61F50 and OSL2), an imaging lens with a focal length of 50 mm, a visible LCTF with a range of 500 nm–710 nm, two relay lenses with a focal length of 75 mm, a DMD (Texas Instruments DLP9500), and a monochromatic CMOS camera (Basler acA2040-90 um).

    Article Title: Plasmonic Titanium Nitride Nanohole Arrays for Refractometric Sensing
    Article Snippet: The imaging and spectroscopy arms of the microscope were separated using two broadband nonpolarizing 50:50 beam splitters (Thorlabs, BS-013). .. The imaging arm was focused on a monochromatic CMOS camera (Basler, model acA4112–30um) using an achromatic doublet (Thorlabs AC254-200-AB). .. The spectroscopy arm was focused on the 10 μm slit of an astigmatism-free Schmidt-Czerny-Turner imaging spectrometer (Princeton Instruments, IsoPlane SCT 320) with a focal length of 320 mm and 150 lines·mm –1 again using an achromatic doublet (Thorlabs AC254-200-AB).

    Article Title: Plasmonic Titanium Nitride Nanohole Arrays for Refractometric Sensing.
    Article Snippet: The imaging and spectroscopy arms of the microscope were separated using two broadband nonpolarizing 50:50 beam splitters (Thorlabs, BS-013). .. The imaging arm was focused on a monochromatic CMOS camera (Basler, model acA4112−30um) using an achromatic doublet (Thorlabs AC254-200-AB). .. The spectroscopy arm was focused on the 10 μm slit of an astigmatismfree Schmidt-Czerny-Turner imaging spectrometer (Princeton Instruments, IsoPlane SCT 320) with a focal length of 320 mm and 150 lines·mm−1 again using an achromatic doublet (Thorlabs AC254-200AB).

    Article Title: High-Performance Plasmonic Hafnium Nitride Nanocavity and Nanodisk Arrays for Enhanced Refractometric Sensing.
    Article Snippet: Two broadband, nonpolarizing 50:50 beam splitters (Thorlabs, BS-013) were utilized to physically separate the spectroscopy and imaging components of the microscope. .. Using an achromatic doublet (Thorlabs AC254-200-AB), the imaging arm was focused on a monochromatic CMOS camera (Basler, model acA4112-30um). .. Again, utilizing an achromatic doublet (Thorlabs AC254-200-AB), the spectroscopy arm was focused on a 10 μm slit on an astigmatism-free Schmidt−Czerny−Turner imaging spectrometer (Princeton Instruments, IsoPlane SCT 320) with a focal length of 320 mm and grating of 150 lines·mm−1.



    Similar Products

    93
    Basler monochromatic cmos camera
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Monochromatic Cmos Camera, supplied by Basler, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/acA2040-180km/pmc12795430-32-8-12
    Average 93 stars, based on 1 article reviews
    monochromatic cmos camera - by Bioz Stars, 2026-11
    93/100 stars
      Buy from Supplier

    95
    Basler mp monochromatic cmos camera
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Mp Monochromatic Cmos Camera, supplied by Basler, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/acA5472-17um/pmc12589536-362-6-10
    Average 95 stars, based on 1 article reviews
    mp monochromatic cmos camera - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    94
    Basler monochromatic board level cmos camera
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Monochromatic Board Level Cmos Camera, supplied by Basler, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/daA3840-45um/pmc12317973-128-4-9
    Average 94 stars, based on 1 article reviews
    monochromatic board level cmos camera - by Bioz Stars, 2026-11
    94/100 stars
      Buy from Supplier

    90
    Basler monochromatic cmos camera ace 2 a2a4200-12gmpro
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Monochromatic Cmos Camera Ace 2 A2a4200 12gmpro, supplied by Basler, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/basler+ace2+camera/10__1016_slash_j__aca__2025__344329-94-7-13
    Average 90 stars, based on 1 article reviews
    monochromatic cmos camera ace 2 a2a4200-12gmpro - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    86
    Thorlabs monochromatic cmos camera
    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − <t>CMOS</t> camera.
    Monochromatic Cmos Camera, supplied by Thorlabs, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/camera+cmos/10__3390_slash_photonics12040314-41-23-28
    Average 86 stars, based on 1 article reviews
    monochromatic cmos camera - by Bioz Stars, 2026-11
    86/100 stars
      Buy from Supplier

    95
    Basler cmos monochromatic camera
    Schematics and working principle of ImOCAS. Side views of the system in the xz ‐ plane (A) yz ‐plane (B). Arrows indicate schematic drop trajectories. All elements are at scale (except the capillary which is twice wider), but the distance between the objective and the <t>CMOS</t> is shortened.
    Cmos Monochromatic Camera, supplied by Basler, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/monochromatic+cmos+camera/acA720-520um/pmc11884609-288-16-20
    Average 95 stars, based on 1 article reviews
    cmos monochromatic camera - by Bioz Stars, 2026-11
    95/100 stars
      Buy from Supplier

    Image Search Results


    Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − CMOS camera.

    Journal: Biomedical Optics Express

    Article Title: qtOCT: quantitative transmission optical coherence tomography

    doi: 10.1364/BOE.580168

    Figure Lengend Snippet: Optical system of t-FF-SS-OCT. SS − swept-source; OI − optical isolator; BS − beam-splitters; CE − cat-eye retroreflector; BE − beam expander; S − sample plane; MO − microscope objective; TL − tube lens; CAM − CMOS camera.

    Article Snippet: The detector used in this system is a monochromatic CMOS camera (acA2040-180-km, Basler) with 5.5 μm pixels arranged in a 2048 x 2048 array, offering a maximum framerate of 180 fps, which puts the limit on the measurement speed as the source offers a 10 000 nm/ s scan speed, which translates to 133.3 full sweeps per second.

    Techniques: Microscopy

    Schematics and working principle of ImOCAS. Side views of the system in the xz ‐ plane (A) yz ‐plane (B). Arrows indicate schematic drop trajectories. All elements are at scale (except the capillary which is twice wider), but the distance between the objective and the CMOS is shortened.

    Journal: Advanced Science

    Article Title: Pheno‐Morphological Screening and Acoustic Sorting of 3D Multicellular Aggregates Using Drop Millifluidics

    doi: 10.1002/advs.202410677

    Figure Lengend Snippet: Schematics and working principle of ImOCAS. Side views of the system in the xz ‐ plane (A) yz ‐plane (B). Arrows indicate schematic drop trajectories. All elements are at scale (except the capillary which is twice wider), but the distance between the objective and the CMOS is shortened.

    Article Snippet: The transmitted light was collected through a zoom lens (1‐60135 6.5×, Navitar) and acquired with a CMOS monochromatic camera (acA720‐520um, Basler) at ≈100 fps.

    Techniques: